  • DJCP01.webp
  • DJCP04.jpg
  • DJCP05.jpg
  • DJCP03.jpg
  • DJCP02.jpg

10.Protective Impregnated Activated Carbon

authentication
  • Commodity name: 10.Protective Impregnated Activated Carbon

Category:

Products

  • Description
  • Product code Application

    Evaluation of product performance

    General Performance

    Protective performance

    XC15-1

    Filled industrial tanks with integrated protection. Can protect against all poisonous gases except CO and perfluoroisobutene. Such as: hydrocyanic acid, arsine, chloropicrin, dichloromethane, mustard gas, benzene, etc.

    Dark black columnar granules,

    Size:1.5mm,Moisture≤3%,Hardness≥70%

    ethylene chloride≥28min

    hydrocyanic acid≥45min

    cyanogen chloride CNCl

    RH=0~50%≥28%min

    RH=75%~50%≥30%min

    XC15-2

    Filling of industrial tanks against acid gases. For example: carbon dioxide, oxygen, chlorine oxides, phosphorus and chlorine-containing organic pesticides, hydrogen sulfide, etc.

    Dark black columnar granules,

    Size:1.5mm,Moisture≤3%,Hardness≥70%

    benzene≥40min

    ethylene chloride≥25min

    hydrocyanic acid≥36nin

    XC15-4

    Filling of industrial tanks, deodorization, protection against helium and hydrogen sulfide at the same time.

    Dark black columnar granules,

    Size:1.5mm,Moisture≤5%,Hardness≥70%

    ammonia (gas)≥40min

    hydrogen sulfide≥16min

    XC15-5

    Filling of industrial cans to protect against mercury vapors.

    Dark black columnar granules,

    Size:1.5mm,Moisture≤5%,Hardness≥70%

    Protection time against mercury vapor≥400h

    XC15-6

    Filling of industrial tanks, deodorization, protection against ammonia and hydrogen sulfide at the same time.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    ammonia (gas)≥50min

    hydrogen sulfide≥30min

    XC09-4

    Filling of industrial tanks, deodorization, protection against helium and hydrogen sulfide at the same time.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    ammonia (gas)≥40min

    Chlorine sulfide≥16min

    XC09-6

    Filled industrial tanks with integrated protection. Can protect against all industrial toxic gases except CO. such as: ammonia, hydrogen sulfide, sulfur dioxide, benzene, etc.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    sulfur dioxide SO2≥50min

    hydrogen sulfide≥30min

    benzene≥80min

    XCO9-14

    Filling of industrial tanks against acid gases. For example: nitrogen dioxide, chlorine, oxides of nitrogen, phosphorus and chlorine-containing organic pesticides, hydrogen sulphide, nitrogen tetroxide, metamethylhydrazine, etc.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    benzene≥45min

    ethylene chloride≥27min

    hydrocyanic acid≥30min

     

    XC07

    Filled industrial tanks with integrated protection. Can protect against all poisonous gases except CO and perfluoroisobutene. Such as: hydrocyanic acid, arsine, chloropicrin, dioxomethane, mustard gas, benzene, etc.

    Dark black columnar granules,

    Size:0.7mm,Moisture≤3%,Hardness≥76%

    ethylene chloride≥30min

    hydrocyanic acid≥50min

    cyanogen chloride CNCl

    RH=0~50%≥28%min

    RH=75%~50%≥30%min

    XC09

    Filled industrial tanks with integrated protection. Can protect against all poisonous gases except CO and perfluoroisobutene. Such as: hydrocyanic acid, arsenic, chloropicrin, methylene chloride, mustard gas, benzene, etc.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    ethylene chloride≥27min

    hydrocyanic acid≥45min

    cyanogen chloride CNCl

    RH=0~50%≥40%min

    RH=75%~50%≥23%min

    XCT09

    Filled industrial tanks with integrated protection. Can protect against all poisonous gases except CO and perfluoroisobutene. Such as: hydrogen emetic acid, hydrogen arsenide, chloropicrin, methylene chloride, mustard gas, benzene, etc.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    ethylene chloride≥27min

    hydrocyanic acid≥45min

    cyanogen chloride CNCl

    RH=0~50%≥40%min

    RH=80%~80%≥23%min

    stereotypes≥23%min

    XC09-5

    Filled industrial tanks with integrated protection. Can protect against all poisonous gases except CO and perfluoroisobutene. Such as: hydrocyanic acid, arsenic, chloropicrin, methylene chloride, mustard gas, benzene, etc.

    Dark black columnar granules,

    Size:0.9mm,Moisture≤3%,Hardness≥76%

    hydrocyanic acid≥45nin

    cyanogen chloride CNCl

    RH=80%~80%≥25%min

    stereotypes≥20%min

     

    XC09

    Filled industrial tanks with integrated protection. Can protect against all poisonous gases except CO and perfluoroisobutene. Such as: hydrocyanic acid, arsenic, chloropicrin, methylene chloride, mustard gas, benzene, etc.

    Dark black columnar granules,

    Size:12×28,Moisture≤3%,Hardness≥76%

    benzene≥45min

    hydrocyanic acid≥30min

    ammonia (gas)≥30min

    hydrogen sulfide≥30min

    KTcatalyzer

    Carbon dioxide purification and protection of sealed spaces such as self-rescuers, mobile mine liferafts and refuge compartments.

    White columnar granules

    Moisture≤3%,Hardness ≥88%,

    Size:1.5m、2.0m、3.0mm

    Carbon dioxide content≤5%

    Nitrogen tetroxide≥24min

Key words:

Protective Impregnated Activated Carbon

Get A Quote

Note: Please leave your email address, our professionals will contact you as soon as possible!